Journal Articles
2012
- Zhen Zhu, Olivier Frey, Diana Silvia Ottoz, Fabian Rudolf, Andreas
Hierlemann, "Microfluidic single-cell cultivation chip with controllable
immobilization and selective release of yeast cells", Lab on a Chip, 2012, 12, 906-915. [Online]
- Simon
Kemmerling, Jörg Ziegler, Gabriel Schweighauser, Stefan A. Arnold,
Dominic Giss, Shirley A. Müller, Philippe Ringler, Kenneth N. Goldie,
Nils Goedecke, Andreas Hierlemann, Henning Stahlberg, Andreas Engel,
Thomas Braun, "Connecting μ-fluidics to electron microscopy", Journal of Structural Biology, 2012, Vol. 177, pp. 128–134. [Online]
- David Jäckel, Urs Frey, Michele Fiscella, Felix Franke and Andreas
Hierlemann, "Applicability of Independent Component Analysis on
High-Density Microelectrode Array Recordings", Journal of Neurophysiology, 2012, in press. [Online]
2011
- J. Rothe, M. K. Lewandowska, F. Heer, O. Frey and A. Hierlemann, "Multi-target electrochemical biosensing enabled by integrated CMOS electronics", Journal of Micromechanics and Microengineering, 2011, 21(5), p. 054010. [Online]
- A.
Hierlemann, U. Frey, S. Hafizovic, F. Heer, “Growing Cells atop
Microelectronic Chips: Interfacing Electrogenic Cells in Vitro with
CMOS-based Microelectrode Arrays", Proceedings of the IEEE, 2011, Vol. 99, No. 2, pp. 252-284. [Online]
- Ian L. Jones, Paolo Livi, Marta K. Lewandowska, Michele Fiscella, Branka
Roscic and Andreas Hierlemann, “The potential of microelectrode arrays
and microelectronics for biomedical research and diagnostics”, Analytical and Bioanalytical Chemistry, 2011, Volume 399 (7), 2313-2329. [Online]
- S.B. Truax, K.S. Demirci, L.A. Beardslee, Y. Luzinova, A. Hierlemann, B. Mizaikoff, O. Brand, "Mass-Sensitive Detection of Gas-Phase Volatile Organics Using Disk Microresonators", Analytical Chemistry, 2011, 83 (9), pp. 3305-3311. [Online]
2010
- U. Frey, J. Sedivy, F. Heer, R. Pedron, M. Ballini, J. Mueller, D. Bakkum, S. Hafizovic, F. D. Faraci, F. Greve, K.-U. Kirstein, and A. Hierlemann, “Switch-matrix-based high-density microelectrode array in CMOS technology”, IEEE Journal of Solid-State Circuits, Vol. 45, no. 2, pp. 467–482, 2010. [Online]
- Ricardo Gutierrez-Osuna and Andreas Hierlemann, "Adaptive Microsensor Systems", Annu. Rev. Anal. Chem. Vol. 3, pp 255–76, 2010. [Online]
- A. Perera, A. Pardo, D. Barrettino, A. Hierlemann, S. Marco, "Evaluation of fish spoilage by means of a single metal oxide sensor under temperature modulation", Sensors and Actuators B, Chemical, 2010, 146, 477-482. [Online]
- Paolo Livi, Flavio Heer, Urs Frey, Douglas J. Bakkum, Andreas Hierlemann, "Compact Voltage and Current Stimulation Buffer for High-Density Microelectrode Arrays", IEEE Transactions on Biomedical Circuits and Systems, Vol. 4, No. 6, 2010, pp. 372-378. [Online]
2009
- Petra Kurzawski, Volker Schurig and Andreas Hierlemann, "Chiral Sensing Using a Complementary Metal−Oxide Semiconductor-Integrated Three-Transducer Microsensor System", Analytical Chemistry, 2009, 81 (22), pp. 9353–9364.
- U. Frey, U. Egert, F. Heer, S. Hafizovic, and A. Hierlemann, “Microelectronic System for High-Resolution Mapping of Extracellular Electric Fields Applied to Brain Slices,” Biosensors and Bioelectronics, vol. 24, no. 7, pp. 2191-2198, 2009. [Online]
- Petra Kurzawski, Anja Bogdanski, Volker Schurig, Reinhard Wimmer and Andreas Hierlemann, "Direct Determination of the Enantiomeric Purity or Enantiomeric Composition of Methylpropionates Using a Single Capacitive Microsensor", Analytical Chemistry, vol. 81, no. 5, pp 1969–1975, 2009.
- Wilfried Weber, Stefan Luzi, Maria Karlsson, Carlota Diaz Sanchez-Bustamante, Urs Frey, Andreas Hierlemann, and Martin Fussenegger, "A synthetic mammalian electro-genetic transcription circuit", Nucleic Acids Research, vol. 37, no. 4, pp. e33, 2009.
- A. Hierlemann, P. Kurzawski, V. Schurig, "The use of different transduction principles for qualitative and quantitative chiral gas analysis", ECS Transactions, 19 (6), 227-239, 2009.
2008
- P. Kurzawski, A. Bogdanski, V. Schurig, R. Wimmer, A. Hierlemann, "Opposite signs of capacitive microsensor signals upon exposure to the enantiomers of methyl propionates", Angew. Chem., International Edition, 2008, 47, 913-916.
- A. Hierlemann, R. Gutierrez-Osuna, "Higher-order Chemical Sensing", Chemical Reviews, 2008, 108, 563-613.
- Antonio Tricoli, Markus Graf, Felix Mayer, Stéphane Kühne, Andreas Hierlemann and Sotiris E. Pratsinis, "Micropatterning Layers by Flame Aerosol Deposition - Annealing", Advanced Materials, 2008, 20, 3005-3010.
- Stéphane Kühne, Markus Graf, Antonio Tricoli, Felix Mayer, Sotiris E. Pratsinis, Andreas Hierlemann "Wafer-level flame-spray-pyrolysis deposition of gas-sensitive layers on microsensors", Journal of Micromechanics and Microengineering, 2008, 18, Article 035040.
- Chunguang Jin, Petra Kurzawski, Andreas Hierlemann, and Edward T. Zellers, “Evaluation of Multi-Transducer Arrays for the Determination of Organic Vapor Mixtures”, Anal. Chem. 2008, 80, 227-236.
- Cyril Vančura, Isabelle Dufour, Stephen M. Heinrich, Fabien Josse, and Andreas Hierlemann, "Analysis of Resonating Microcantilevers Operating in a Viscous Liquid Environment", Sensors and Actuators A, Physical, 2008, 141, 43-51.
- M. Zimmermann, T. Volden, K.-U. Kirstein, S. Hafizovic, J. Lichtenberg, Oliver Brand, and A. Hierlemann, "A CMOS-Based Integrated-System Architecture for a Static Cantilever Array", Sensors & Actuators: B. Chemical, 2008, 131, 254-264.
- C. D. Sanchez-Bustamante, U. Frey, J. M. Kelm, A. Hierlemann, and M. Fussenegger, "Modulation of Cardiomyocyte Electrical Properties Using Regulated Bone Morphogenetic Protein-2 Expression," Tissue Engineering Part A, 2008, 14(12), 1969-1988.
- Yue Li, Cyril Vancura, Kai-Uwe Kirstein, Jan Lichtenberg, Andreas Hierlemann, "Monolithic Resonant cantilever-based CMOS Microsystem for Biochemical Sensing" , IEEE Transactions on Circuits and Systems I: Regular Papers, 2008, Volume 55, Issue 9, 2551 - 2560.
2007
- U. Frey, M. Graf, S. Taschini, K.-U. Kirstein, A. Hierlemann, "A digital CMOS architecture for a micro-hotplate array", IEEE Journal of Solid-State Circuits, Vol. 42, No. 2, February 2007, p. 441-450.
- D. Barrettino, P. Malcovati, M. Graf, S. Hafizovic, A. Hierlemann
”CMOS-based monolithic controllers for smart sensors comprising micromembranes and microcantilevers”, IEEE Transactions on Circuits and Systems – 1: Regular Papers, Vol. 54. No. 1, January 2007, p. 141-152.
- W. Franks, S. Tosatti, F. Heer, P. Seif, M. Textor, A. Hierlemann, ”Patterned cell adhesion by self-assembled structures for use with a CMOS cell-based biosensor”, Biosensors and Bioelectronics 22 (2007), p. 1426-1433.
- F. Heer, S. Hafizovic, T. Ugniwenko, U. Frey, W. Franks, E. Perriard, J.-C. Perriard, A. Blau, C. Ziegler, A. Hierlemann, “Single-chip microelectronic system to interface with living cells“, Biosensors and Bioelectronics 22 (2007), p. 2546-2553.
- F. Greve, J. Lichtenberg, K.-U. Kirstein, U. Frey, J.-C. Perriard, A. Hierlemann,
“A perforated CMOS microchip for immobilization and activity monitoring of electrogenic cells”, Journal of Micromechanics and Microengineering, 17 (2007) p. 4562-471.
- C. Vancura, Y. Li, J. Lichtenberg, K.-U. Kirstein, A. Hierlemann, “Liquid-phase chemical and biochemical detection using fully integrated magnetically actuated complementary metal oxide semiconductor resonant cantilever sensor systems“, Analytical Chemistry, Vol. 78, No. 4 (2007), p. 1646-1654.
- S. Hafizovic, F. Heer, T. Ugniwenko, U. Frey, A. Blau, C. Ziegler, A. Hierlemann, "A CMOS-based microelectrode array for interaction with neuronal cultures” Journal of Neuroscience Methods, Vol. 164 (2007), p. 93-106.
- O. Frey, S. Bonneick, A. Hierlemann, J. Lichtenberg, "Autonomous microfluidic multi-channel chip for real-time PCR with integrated liquid handling”, Biomedical Microdevices 9 (2007) p. 711-718.
- F. Greve, L. Seemann, A. Hierlemann, J. Lichtenberg, "A hybrid microsystem for parallel perfusion experiments on living cells“, Journal of Micromechnics and Microengineering, Vol. 17 (2007) 1721-1730.
- Y. Li, C. Vancura, D. Barrettino, M. Graf, C. Hagleitner, A. Kummer, M. Zimmermann, K.-U. Kirstein, A. Hierlemann, “Monolithic CMOS multi-transducer gas sensor microsystem for organic and inorganic analytes“, Sensors and Actuators B, Vol. 126 (2007) 431-440.
- F. Greve, S. Frerker, A.G. Bittermann, C. Burkhardt, A. Hierlemann, H. Hall
"Molecular design and characterization of the neuron-microelectrode array interface“, Biomaterials 28 (2007) p. 5246-5258.
2006
- A. Kummer, A. Hierlemann, “Configurable electrodes for capacitive-type sensors and chemical sensors”, IEEE Sensors Journal, Vol. 6, No. 1, February 2006, pp 3-10.
- A. Kummer, T. Burg, A. Hierlemann, "Transient signal analysis using complementary metal oxide semiconductor capacitive chemical microsensors", Analytical Chemistry, Vol. 78, No. 1, January 2006, pp 279-290.
- T. Kraus, E. Verpoorte, V. Linder, W. Franks, A. Hierlemann, F. Heer, S. Hafizovic, T. Fujii, N. de Rooij, S. Koster, "Characterization of a microfluidic dispensing sytem for localised stimulation of cellular networks", Lab Chip, 6, 2006, pp 218-229.
- D. Barrettino, M. Graf, S. Taschini, S. Hafizovic, C. Hagleitner, A. Hierlemann, "CMOS monolithic metal-oxide gas sensor microsystems", IEEE Sensor Journal, Vol. 6, No. 2, 2006, pp. 276-286.
- V. Linder, S. Koster, W. Franks, T. Kraus, E. Verpoorte, F. Heer, A. Hierlemann, N.F. de Rooij, "Microfluidics/CMOS orthogonal capabiliies for cell biology", Biomedical Microdevices 8 (2006) 159-166.
- F. Heer, S. Hafizovic, W. Franks, A. Blau, C. Ziegler, A. Hierlemann, "CMOS microelectrode array for bidirectional interaction with neuronal networks", IEEE Journal of Solid-State Circuits, Vol. 41, No. 7 (2006) 1620-1629.
- P. Kurzawski, T. Salo, H. Baltes, A. Hierlemann, "Towards a versatile DRIE: Silicon Pit structures combined with electrochemical etch Stop", Journal of Microelectromechanical Systems, Vol. 15, No. 4 (2006) 840-848.
- M. Graf, U. Frey, S. Taschini, A. Hierlemann, "Micro hot plate-based sensor array system for the detection of environmentally relevant gases", Analytical Chemistry, Vol. 78, No. 19 (2006) 6801-6808.
- P. Kurzawski, C. Hagleitner, A. Herlemann, "Detection and discrimination capabilities of a multitransducer single-chip gas sensor system", Analytical Chemistry, Vol. 78, No. 19 (2006) 6910-6920.
- M. Graf, D. Barrettino, K.-U. Kirstein, A. Hierlemann, "CMOS microhotplate sensor system for operating temperatures up to 550°C", Sensors and Actuators B 117 (2006) 346-352.
- J.M. Kelm, V. Djonov, S.P. Hoerstrup,, C.I. Guenter, L.M. Ittner, F. Greve, A. Hierlemann, C.D. Sanchez-Bustamante, J.-C. Perriard, E. Ehler, M. Fussenegger, "Tissue-transplant fusion and vascularization of myocardial microtissues and macrotissues implanted into chicken embryos and rats", Tissue Engineering, Vol. 12, No. 9 (2006) 1 – 13.
Received the 2006 ESAO (European Society of Artificial Organs) Research Award
- G. Romera-Guereca, J. Lichtenberg, A. Hierlemann, D. Poulikakos, B. Kang, "Explosive vaporization in microenclosures", Experimental Thermal and Fluid Science 30 (2006) 829-836.
- M. Graf, A. Gurlo, N. Barsan, U. Weimar, A. Hierlemann, "Microfabricated gas sensor system with sensitive nanocrystalline metal-oxide films", Journal of Nanoparticle Research 8 (2006) 823-839.
2005
- M. Graf, R. Jurischka, D. Barrettino, and A. Hierlemann, “3-D nonlinear modelling of microhotplates in CMOS technology for use as metal-oxide-based gas sensors”, Journal of Micromechanics and Microengineering 15 (2005) 190-200.
- D. Barrettino, S. Hafizovic, T. Volden, J. Sedivy, K.-U. Kirstein, A. Hierlemann, "CMOS monolithic mechatronic microsystem for surface imaging and force response studies“, IEEE Journal of Solid-State Circuits 40 (2005) 951-959.
- M. Graf, S.K. Müller, D. Barrettino, A. Hierlemann,"Transistor heater for microhotplate-based metal-oxide microsensors", IEEE Electron Device Letters 26 (2005) 295-297.
- C. Vancura, M. Rüegg, Y. Li, C. Hagleitner, A. Hierlemann, "Magnetically actuated complementary metal oxide semiconductor resonant cantilever gas sensor systems“, Analytical Chemistry 77 (2005) 2690-2699.
- W. Franks, I. Schenker, P. Schmutz, A. Hierlemann, “Impedance characterization and modeling of electrodes for biomedical applications”, IEEE Transactions on Biomedical Engineering 52 (2005) 1295-1302.
- C. Vancura, J. Lichtenberg, A. Hierlemann, "Characterization of magnetically actuated resonant cantilevers in viscous fluids", Applied Physics Letters 87, (2005) 87-89.
- T. Bechtold. E- B. Rudnyi, J.G. Korvink, M. Graf, A. Hierlemann, "Connecting heat transfer macromodels for array MEMS structures“, Journal of Micromechanics and Microengineering 15 (2005) 1205-1214.
- A. Hierlemann, "Integrated chemical microsensor systems in CMOS technology", LabPlus international, Vol. 19, No. 4, Sept. 2005, 14-18.
2004
- S. Hafizovic, D. Barrettino, T. Volden, J. Sedivy, K.-U. Kirstein, O. Brand, A. Hierlemann, “Single-chip mechatronic microsystem for surface imaging and force response studies”, PNAS, Vol. 101, No. 49 (2004) 17011-17015.
- M. Graf, D. Barrettino, M. Zimmermann, A. Hierlemann, H. Baltes, S. Hahn, N. Bârsan, U. Weimar, “CMOS monolithic metal-oxide sensor system comprising a microhotplate and associated circuitry”, IEEE Sensor Journal, Vol. 4 (2004) 9-16.
- A. Kummer, A. Hierlemann, H. Baltes, "Tuning Sensitivity and Selectivity of complementary metal oxide semiconductor-based capacitive chemical microsensors“, Analytical Chemistry 76 (2004) 2470-2477.
- M. Graf, D. Barrettino, S. Taschini, C. Hagleitner, A. Hierlemann, H. Baltes, “Metal oxide-based monolithic complementary metal oxide semiconductor gas sensor microsystem”, Analytical Chemistry 76 (2004) 4437-4445.
- D. Barrettino, M. Graf, W.H. Song, K.-U. Kirstein, A. Hierlemann, H. Baltes, “Hotplate-based monolithic CMOS microsystems for gas detection and material characterization for operating temperatures up to 500°C”, IEEE Journal of Solid-State Circuits 39 (2004) 1202-1207.
- D. Barrettino, M. Graf, M. Zimmermann, C. Hagleitner, A. Hierlemann, H. Baltes, “A smart single-chip micro-hotplate-based gase sensor system in CMOS-technology”, Int. Journal on Analog Integrated Circuits and Signal Processing 39 (2004) 275-287.
- F. Heer, W. Franks, A. Blau, S. Taschini, C. Ziegler, A. Hierlemann, H. Baltes, “CMOS microelectrode array for the monitoring of electrogenic cells”, Biosensors & Bioelectronics 20 (2004) 358-366.
- M. Jenkner, M. Tartagni, A. Hierlemann, and R. Thewes, “Cell-Based CMOS Sensor and Actuator Arrays”, IEEE Journal of Solid-State Circuits, Vol. 39, No. 12 (2004) 24312437.
2003
- A. Hierlemann, O. Brand, C. Hagleitner, H. Baltes, "Microfabrication techniques for chemical/biosensors", Proceedings of the IEEE, 91 (6), 2003, 839-863. ISSN 0018-9219
- A. Hierlemann, H. Baltes, "CMOS-based chemical microsensors", The Analyst, 128 (1), 2003, pp. 15-28.
2002
- W. Franks, D. Lange, S. Lee, A. Hierlemann, N. Spencer, H. Baltes, "Nanochemical surface analyzer in CMOS technology", Ultramicroscopy, 91 (1-4), 2002, 21 - 27. ISSN 0304-3991
- D. Lange, C. Hagleitner, A. Hierlemann, O. Brand, H. Baltes, "Complementary Metal Oxide Semiconductor Cantilever Arrays on a Single Chip: Mass-Sensitive Detection of Volatile Organic Compounds", Analytical Chemistry, 2002, 74 (13). pp. 3084-3095.
2001
- C. Hagleitner, A. Hierlemann, D. Lange, A. Kummer, N. Kerness, O. Brand, H. Baltes, "Smart single-chip gas sensor microsystem", Nature, 414 (6861), 2001, p. 293. ISSN 00280836
- A. Hierlemann,H. Baltes, V. Schurig, "Search for extraterrestrial enantioenrichment by using chemical microsensors", Enantiomer, 6 (2-3), 2001, pp. 129-139. ISSN 1024-2430
- A. Hierlemann, E.T. Zellers, A.J. Ricco, "Use of Linear Solvation Energy Relationships for Modeling Responses from Polymer-Coated Acoustic-Wave Vapor Sensors", Analytical Chemistry, 73 (14), 2001, pp. 3458-3466.
2000
- A. Hierlemann, A.J. Ricco, K. Bodenhöfer, A. Dominik, W. Göpel, Conferring Selectivity to Chemical Sensors via Polymer Side-Chain Selection: Thermodynamics of Vapor Sorption by a Set of Polysiloxanes on Thickness-Shear Mode Resonators, Anal Chem. 72 (2000) 3696-3708.
- A. Hierlemann, A. Koll, D.Lange, C. Hagleitner, N. Kerness, O. Brand, H. Baltes, Application-Specific Sensor Systems Based on CMOS Chemical Microsensors, Sensors and Actuators B, 70 (2000) 2-11.
Before 2000
- A. Hierlemann, A.J. Ricco, K. Bodenhöfer, W. Göpel, Effective Use of Molecular Recognition in Gas Sensing: Results from Acoustic Wave and In-Situ FTIR Measurements, Anal. Chem. 71 (1999) 3022-3035.
- A. Hierlemann, K. Bodenhöfer, M. Juza, B. Gross, V. Schurig, W. Göpel, Enantioselective Monitoring of Chiral Inhalation Anesthetics by Simple Gas Sensors, Sensors and Materials 11, 4 (1999) 209-218.
- R.C. Thomas, A. Hierlemann, A.W. Staton, M. Hill, and A.J. Ricco, Reflectance Infrared Spectroscopy on Operating Surface Acoustic Wave Chemical Sensors during Exposure to Gas-Phase Analytes, Anal. Chem. 71 (1999) 3615-3621.
- A. Hierlemann, J.C. Campbell, L. Baker, R.M. Crooks, A.J. Ricco, Structural Distortion of Dendrimers on Gold Surfaces: A Tapping-Mode AFM Investigation, J. Am. Chem. Soc. 120 (1998) 5323-5324.
- K. Bodenhöfer, A. Hierlemann, W. Göpel, M. Juza, B. Gross and V. Schurig, Efficient Gas Sensor Mediated Enantiomer Discrimination of 2-Substituted Methyl Propionates and Chiral Inhalation Anaesthetics on a Modified Cyclodextrin, Chimica OGGI-Chemistry Today, 16 (1998) 56-58.
- K. Bodenhöfer, A. Hierlemann, J. Seemann, G. Gauglitz, B. Koppenhoefer, W. Göpel, Chiral Discrimination using Piezoelectric and Optical Gas Sensors, Nature 387 (1997) 577-580.
- K. Bodenhöfer, A. Hierlemann, J. Seemann, G. Gauglitz, W. Göpel, Chiral Discrimination in the Gas Phase Using Different Transducers: Thickness Shear Mode Resonators and Reflectometric Interference Spectroscopy, Anal. Chem. 69 (1997) 3058-3068.
- K. Bodenhöfer, A. Hierlemann, R. Schlunk, and W. Göpel, New Method of Vaporising Volatile Organics for Gas Tests, Sens. Actuators B 45/3 (1997) 259-264.
- K. Bodenhöfer, A. Hierlemann, M. Juza, V. Schurig, W. Göpel, Chiral Discrimination of Inhalation Anesthetics and Methyl Propionates by Thickness Shear Mode Resonators: New Insights into the Mechanisms of Enantioselectivity by Cyclodextrins, Anal. Chem., 69 (1997) 4017-4031.
- R. Zhou, A. Hierlemann, U. Weimar, W. Göpel, Gravimetric, Dielectric and Calorimetric Methods for the Detection of Organic Solvent Vapours Using Polyetherurethane Coatings, Sens. Actuators B 34 (1996) 356.
- Marco, A. Pardo, F. Davide, C. DiNatale, A. D'Amico, A. Hierlemann, W. Göpel, Different Strategies for the Dynamic Calibration of Gas Sensors, Sens. Actuators B 34 (1996) 213-223.
- A. Hierlemann, K. Bodenhöfer, M. Fluck, V. Schurig, W. Göpel, Selective Detection of Nitrogen- and Oxygen-Containing Analytes Using Metal-Modified Polysiloxanes, Anal. Chim. Acta, 346 (1997) 327-339.
- A. Hierlemann, K. Bodenhöfer, G. Noetzel, U. Weimar, W. Göpel, Performances of Mass-Sensitive Devices, Anal. Chem. 68 (1996) 2210-2218.
- R. Zhou, A. Hierlemann, K.D. Schierbaum, K.E. Geckeler, W. Göpel, Detection of Organic Solvents with Reliable Chemical Sensors Based on Cellulose Derivatives, Sens. Actuators B 24-25 (1995) 443-447.
- C. DiNatale, F. Davide, A. D'Amico, A. Hierlemann, J. Mitrovics, M. Schweizer, U. Weimar, W. Göpel, A composed neural net for the recognition of gas mixtures, Sens. Actuators B 24-25 (1995) 808-812.
- F.A.M. Davide, C. DiNatale, A. D'Amico, A. Hierlemann, J. Mitrovics, M. Schweizer, U. Weimar, W. Göpel, Structure Identification of Nonlinear Models for QMB Polymer-Coated Sensors, Sens. Actuators B 24-25 (1995) 830-842.
- C. Cornila, A. Hierlemann, R. Lenggenhager, P. Malcovati, H. Baltes, G. Noetzel, U. Weimar, W. Göpel, Capacitive Sensors in CMOS Technology with Polymer Coating, Sens. Actuators B 24-25 (1995) 357-361.
- A. Hierlemann, U. Weimar, G. Kraus, G. Gauglitz, W. Göpel, Environmental Chemical Sensing Using Quartz Microbalance Sensor Arrays: Application of Multicomponent Analysis Techniques, Sens. Materials 7 (3) (1995) 179-189.
- J.W. Gardner, A. Pike, N. F. de Rooij, M. Koudelka-Hep, P. Clerc, A. Hierlemann, W. Göpel, Integrated Array Sensor for Detecting Organic Solvents, Sens. Actuators B 26-27 (1995) 135-139.
- F.A.M. Davide, C. DiNatale, A. D'Amico, A. Hierlemann, J. Mitrovics, M. Schweizer, U. Weimar, W. Göpel, S. Marco, A. Pardo, Dynamic Calibration of QMB Polymer-Coated Sensors by Wiener Kernel Estimation, Sens. Actuators B 26-27 (1995) 275-285.
- M. Schweizer, J. Göppert, A. Hierlemann, J. Mitrovics, U. Weimar, W. Rosenstiel, W. Göpel, Application of Neural Network Systems to the Dynamic Response of Polymer-Based Sensor Arrays, Sens. Actuators B 26-27 (1995) 232-236.
- A. Hierlemann, U. Weimar, G. Kraus, M. Schweizer, W. Göpel, Polymer-Based Sensor Arrays and Multicomponent Analysis for the Detection of Hazardous Organic Vapours in the Environment, Sens. Actuators B 26-27 (1995) 126-134.
- K.D. Schierbaum, A. Hierlemann, W.Göpel, Modified Polymers for Reliable Detection of Organic Solvents, Sens. Actuators B 18-19 (1994) 448-452.
Wichtiger Hinweis:
Diese Website wird in älteren Versionen von Netscape ohne
graphische Elemente dargestellt. Die Funktionalität der
Website ist aber trotzdem gewährleistet. Wenn Sie diese
Website regelmässig benutzen, empfehlen wir Ihnen, auf
Ihrem Computer einen aktuellen Browser zu installieren. Weitere
Informationen finden Sie auf
folgender
Seite.
Important Note:
The content in this site is accessible to any browser or
Internet device, however, some graphics will display correctly
only in the newer versions of Netscape. To get the most out of
our site we suggest you upgrade to a newer browser.
More
information